Contact Local Building or Fire Officials about Restriction and Installation Inspections in you area as well as National Codes:
Please refer to appliance manufacturer's instructions to determine proper sizing and connection of venting system to appliance,
including maximum horizontal length, maximum height, and installation clearances (air spaces). The proper operation of the vent
system and appliance requires parts specified by Z-FLEX with no deletion or substitutions.
Z-FLEX recommends that an experienced professional who works with venting system on a regular basis perform the
installation. These instructions are intended as a guide to assist a professional installer.
When the Z-VENT system is installed, the following should be observed:
1. A venting system that exits the structure through a sidewall or the like, shall terminate not less than 12 inches (254 mm) above
the ground (see Illustration #2, Page 5)
2. The termination of a system shall be located above the snow line in geographical areas where snow accumulates. The termination
area should be kept clear of snow and ice at all times.
3. The vent shall not terminate less than 7 ft. (2.13m) above a paved sidewalk or driveway.
4. The termination shall be 6 ft. (1.8 m) or more from the combustion air intake of any appliance.
5. The system shall terminate more than 3 ft. (.91 m ) from any other building opening, gas utility meter, service regulator, or the like.
6. Exterior mounted venting systems should be enclosed below the roof line with a chase to limit condensation and protect against
mechanical failure.
NOTES:
A. The Z-FLEX SPECIAL STAINLESS VENT SYSTEM is for use only with appliances having a positive vent pressure of 8" of water
column or less.
B. Except for installation in one or two family dwellings, a venting system that extends through any zone above that on which the
connected appliances located shall be provided with an enclosure having fire resistance rating equal to or greater than that of the
floor or roof assemblies through which it passes.
C. Do not place any type of insulation in any required air spaces surrounding the vent system.
D. A termination must be used on all installations to assure proper operation and to prevent debris from entering the venting system.
E. The Z-Vent system must be free to expand and contract. Pipe must be properly supported. Vertical runs must us firestops as
lateral support at each ceiling level and at least one support collar at the base of the vertical run. For vertical runs exceeding 16'
(4.88 m), a support collar is required at 16' (4.88 ,m) intervals. Horizontal runs require a loose fitting metal strap or similar support
at each joint.
F. Examine all components for possible shipping damage prior to installation.
G. Proper joint assembly is essential for a safe installation. Follow these instruction exactly as written. Check severeness of joints
upon completion of assembly.
H. Check for unrestricted vent movement through walls, ceilings and roof penetrations.
I. Different manufacturers have different joint systems and adhesives. Do Not Mix Pipe, Fittings or Joining methods from
different manufacturers.
10 Foot Pipe
SPECIAL STAINLESS STEEL VENTING
For use with Category II, III, IV appliances
COMPONENT 3" SYSTEM CAT. # COMPONENT 3" SYSTEM CAT. #
SVEPWC0310 Adjust. Flashing SVSADJ03
Reducer 4" to 3"
SVSSCX03
GE106X
SVSRCX03
SVSLSX03
Flat Flashing
Locking Band
Firestop Support
Firestop Spacer
SVSTPX03
SVSACA03
SVEWMFA03
SVSERWC0403
SVSSCS03
SVSLBX03
SVSFSS03
SVSFSX03
SVSTTX03
SVSRTX03
WM CGI Starter
SVEPWC0308
Storm Collar
Z-Vent Sealant
WM Term Coupling
Ametek Fan Conn.
Termination Tee
Termination Box
Rain Cap
Top Support
2 Foot Pipe
1 Foot Pipe
6 Inch Pipe
90 Elbow
8 Foot Pipe
5 Foot Pipe
4 Foot Pipe
3 Foot Pipe
Vertical Drain Tee
Wall Thimble
WM GV Starter
SVEDTK
SVEVWC03
SVSWTX03
SVEWMG03
SVEEWC0390
SVEEWC0345
SVEDWC03Horizontal Drain Tee
45 Elbow
USA - National fuel gas code ANSI-Z223.1
CANADA - CAN/CGA-B149.1 or .2 Fuel Burning Installation Code
PARTS LIST
Drain Tube Kit
SVEPWC0305
SVEPWC0304
SVEPWC0303
SVEPWC0302
SVEPWC0301
SVEPWC03.5